EDR/HDR Test DCPs | Meters without Tools

6 new sets of test files have been loaded onto the Download site. They all deal with the extreme low light levels of cinema extended dynamic range (Cinema HD) and are hopefully usable with Cinema Standard Def as well.

Note: These are available and usable now…but after some testing they are being modified to be a little more user cuddly…labels being expanded, and the like. Fill out the form below if you want to know when the updates are available. Expect that to be on 13 July, after testing them again.

They all include scales of some sort (see the PNGs below). All include a range of  sets, some that can only be seen on extremely low light HDR / EDR projector systems and some probably only appropriate for P3 systems. The DCP will also include one or two sets that are in between those extremes…6% of each color going to 0% might be one extreme…while the other extreme is 1.5 – 0% of each color.

Please experiment and give feedback.

In addition to seeing what can be seen, the purpose is to do the impossible: Provide a maintenance tool that, with regular use, can objectively show color and contrast stability or degradation in the projection system – without the use of expensive devices and usable by non-technical (though trained) personnel between calibrations.

All are further described on their download pages, and on the TIFF files pages that the DCPs were derived from. They are constrained to 52.37 cd/m2.

The pass code for all downloads is QA_b4_QC

10 boxes, 4 colors DCPS

Rotary Contrast Dial DCPS

Grey Steps Filled with Numbers

Vertical Contrast Meters DCP


The pointers to the following TIFFs are included until their DCP is created. Like the above they are 4096 x 2160. But the blocks are 1000 x 1000 pixels…therefore the “pictures” are 4000 x 2000 surrounded by black.

White To Black with Scales

Primaries and Secondaries with Scales

The DCPs were all created with 20 bit, 2020 Color Space TIFF files, which can also be downloaded and used in your own tests – the TIFF site is referenced in the DCP description or on this page: DCP TIFFs

We are looking for and appreciative of any comments – obviously corrections needed, but also ideas to tweak the project forward. Training Lessons and Checklists will come after figuring out which slides are valuable for which systems.

Thank you. C J Flynn.

[caldera_form id=”CF5d02be68ed6a8″]

A Dial of Red from 4.5% to 0% with tics 5 percent Solution Scope PNG Sample of the Green colors with outline

Grey Steps x 40
Perfectly smooth the TIFF file is, excepting for the Mach Effect…but the key is in the numbers laid on top…which row can be seen by which system? …does it get worse with time? …dirty lens? …dirty port glass? …dirty screen?
Numbers laid onto the grey steps x 40
Which of these numbers can the test person see when these number are laid on top of the boxes…The top is 65353 (16 bits of white) x [Box Number] x .9999, the next is 65353 x BN x .999 and the 3rd is 65353 x BN x .99

 

 

4 pictures of different test files types
4 pictures of different test files types

 

Quality Assurance Tools and News for Cinema Exhibition